A
A.1 Parameter list
A-851
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1786:5 PKW data received, PROFIBUS (–> 2.4)
Min Standard Max Unit Data type Effective
Hex Unsigned16 RO
... is an image of the PKW data received by the DP slave.
The sub-parameter
with index 0 contains the number of valid words
= 0 ––> no PKW data available
= 4 ––> PKW data available
with index 1 of the PKE word (PKE: Parameter identification)
with index 2 of the IND word (IND: Sub-index, sub-parameter number, array index)
with index 3 of the most significant PWE word (PWE: Parameter value)
with index 4 of the least-significant PWE word
Note: refer to the index entry ”PKW area”
1787:5 PKW data sent, PROFIBUS (–> 2.4)
Min Standard Max Unit Data type Effective
Hex Unsigned16 RO
... is an image of the PKW data sent to the DP master.
The sub-parameter
with index 0 contains the number of valid words
= 0 ––> no PKW data available
= 4 ––> PKW data available
with index 1 of the PKE word (PKE: Parameter identification)
with index 2 of the IND word (IND: Sub-index, sub-parameter number, array index)
with index 3 of the most significant PWE word (PWE: Parameter value)
with index 4 of the least-significant PWE word
Note: refer to the index entry ”PKW area”
1788:17 Processed data received via PROFIBUS
Min Standard Max Unit Data type Effective
Hex Unsigned16 RO
... is an image of the process data received by the DP slave (control words).
The sub-parameter
with index 0 contains the number of valid words,
with index 1, the process data 1 (control word 1), with index 2, the process data 2 (PZD2), ...
Note: refer to the index entry ”Process data”
1789:17 Process data sent via PROFIBUS
Min Standard Max Unit Data type Effective
Hex Unsigned16 RO
... is an image of the process data sent to the DP master (status words).
The sub-parameter
with index 0 contains the number of valid words,
with index 1, process data 1 (status word 1), with index 2, process data 2 (PZD2), ...
Note: refer to the index entry ”Process data”