A.1 Parameter list
A-852
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1790 Meas. circ. type indirect meas. system
Min Standard Max Unit Data type Effective
Integer16 RO
... displays which measuring system type is used.
0 Encoder with sin/cos 1 Vpp signals
7 TTL encoder (new basic module HR)
11 Encoder with sin/cos 1 Vpp voltage signals with a higher resolution
13 Resolver with higher resolution (14 bit)
14 Resolver (12 bit)
16 EnDat encoder (absolute value encoder)
27 EnDat encoder (absolute value encoder) with higher incremental track resolution
1792 Active measuring system (–> 3.3)
Min Standard Max Unit Data type Effective
Unsigned16 RO
... indicates the measuring system which the drive control uses.
0 No measuring system
1 Motor measuring system
2 Direct measuring system
1794 Option mod. (PROFIBUS): Version initial progr. loader (–> 3.1)
Min Standard Max Unit Data type Effective
Unsigned32 RO
... indicates which version of the initializer is on the option module.
Example: P1794 = 10104 ––> V01.01.04 is available
1795 Option module (PROFIBUS): Version firmware
Min Standard Max Unit Data type Effective
Unsigned32 RO
... displays the firmware version on the option module.
Example: P1795 = 10104 ––> V01.01.04 is available
1796 Initializer version
Min Standard Max Unit Data type Effective
Unsigned32 RO
... displays which version of the initializer is available on the memory module.
Example: P1796 = 10104 ––> V01.01.04 is available
1798 Firmware date
Min Standard Max Unit Data type Effective
Unsigned32 RO
Internal Siemens
... displays when the firmware release (P1799) was generated.
Note: yyyymmdd ––> yyyy = year, mm = month, dd = day
1799 Firmware version
Min Standard Max Unit Data type Effective
Unsigned32 RO
... displays the firmware version on the memory module.
Example: P1799 = 10103 ––> V01.01.03 is available