A.1 Parameter list
A-854
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1814 Measuring function meas. type
Min Standard Max Unit Data type Effective
1 1 8 – Unsigned16 immed.
Note: refer to the index entry ”Measuring function”
1815 Measuring function meas. period (step change)
Min Standard Max Unit Data type Effective
1 100 2000 ms Unsigned16 immed.
Note: refer to the index entry ”Measurement function”
1816 Measuring function settling time
Min Standard Max Unit Data type Effective
0 100 65535 ms Unsigned16 immed.
Note: refer to the index entry ”Measurement function”
1817 Measuring function no. of averaging ops. (FFT)
Min Standard Max Unit Data type Effective
1 16 1000 – Unsigned16 immed.
Note: refer to the index entry ”Measurement function”
1820 Signal number test socket 1
Min Standard Max Unit Data type Effective
0 8 530 – Unsigned16 immed.
The parameter defines which signal is output via test socket 1.
The signal number from the signal selection list for analog outputs must be entered.
Note: refer to the index entry ”Test sockets”
1821 Shift factor test socket 1
Min Standard Max Unit Data type Effective
0 6 47 – Unsigned16 immed.
... defines the shift factor, with which the analog signal is manipulated.
An 8 bit window of the 24/48 bit signal can be represented via the test socket, thus, the shift
factor must be used to define which window of the internal 24/48 bits is to be displayed.
1822 Offset test socket 1
Min Standard Max Unit Data type Effective
–128 0 127 – Integer16 immed.
The parameter specifies the offset value which is added to the 8-bit output signal.
Note: refer to the index entry ”Test sockets”
1823 Segment address test socket 1
Min Standard Max Unit Data type Effective
0 0 1 – Unsigned16 immed.
Note: Internal Siemens
1824 Offset address test socket 1
Min Standard Max Unit Data type Effective
0 0 FFFFFF Hex Unsigned32 immed.
Note: Internal Siemens