EasyManua.ls Logo

Siemens SINAMICS G150 - Page 157

Siemens SINAMICS G150
680 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical installation
4.10 Other connections
Converter cabinet units
Operating Instructions, 07/2016, A5E03347396A
157
Table 4- 52 Specification of measuring systems that can be connected
Parameters
Designation
Threshold
4)
Min.
Max.
Unit
High signal level
(TTL bipolar at X520 or X521/X531)
1)
U
Hdiff
2 5 V
Low signal level
(TTL bipolar to X520 or X521/X531)
1)
U
Ldiff
-5 -2 V
High signal level
(HTL unipolar)
U
H
4)
High
17
V
CC
V
Low
10
V
CC
V
Low signal level
(HTL unipolar)
U
L
4)
High
0
7
V
Low
0
2
V
High signal level
(HTL bipolar)
2)
U
Hdiff
3 V
CC
V
Low signal level
(HTL bipolar)
2)
U
Ldiff
-V
CC
-3 V
Signal frequency
f
S
-
300
kHz
Edge spacing
t
min
100
-
ns
Zero pulse inactive time
(before and after A=B=high)
t
Lo
640 (t
ALo-BHi
- t
Hi
)/2
3)
ns
Zero pulse active time
(while A=B=high and beyond)
t
Hi
640 t
ALo-BHi
- 2 x t
Lo
3)
ns
1)
Other signal levels according to the RS 422 standard.
2)
The absolute level of the individual signals varies between 0 V and V
CC
of the measuring system.
3)
t
ALo-BHi
is not a specified value, but is the time between the falling edge of track A and the next but one rising edge of
track B.
4)
The threshold can be set via p0405.04 (switching threshold); the setting on delivery is "Low."
Figure 4-37 Signal characteristic of the A and B track between two edges: time between two edges
with pulse encoders

Table of Contents

Other manuals for Siemens SINAMICS G150

Related product manuals