Functions, monitoring, and protective functions
9.4 Monitoring and protective functions
Converter cabinet units
Operating Instructions, 07/2016, A5E03347396A
587
Thermal motor model 2 (for induction motors)
p0344
p0612
figuration
p0617
Stator thermally relevant iron component
p0618
Stator thermally relevant copper component
p0619
Rotor thermally relevant mass
p0625
Motor ambient temperature
p0626
Motor overtemperature, stator iron
p0627
Motor overtemperature, stato
r winding
p0628
Motor overtemperature, rotor winding
r0630
Mot_temp_mod ambient temperature
r0631
Mot_temp_mod stator iron temperature
r0632
Mot_temp_mod stator winding temperature
r0633
Mot_temp_mod rotor temperature
Temperature measurement via TM150 (option G51)
9.4.6.1
The Terminal Module 150 (TM150) has 6x 4-pole terminals for temperature sensors.
Temperature sensors can be connected in a 1x2, 1x3 or 1x4-wire system. In a 2x2-wire
system, up to 12 input channels can be evaluated. 12 input channels can be evaluated in the
factory setting. The temperature channels can be combined into three groups and evaluated
together.
PTC, KTY84, bimetallic NC contact, PT100 and PT1000 temperature sensors can be
connected and evaluated. The fault and/or alarm thresholds of the temperature values can
be set from -99° C up to 251° C.
The temperature sensors are connected at terminal strips X531 to X536 according to the
following table.
The TM150 temperature inputs are not electrically isolated.