Setpoint channel and closed-loop control
7.2 Setpoint channel
Converter cabinet units
420 Operating Instructions, 07/2016, A5E03347396A
At certain points in this chapter, reference is made to function diagrams. These can be found
on the customer DVD in the "SINAMICS G130/G150 List Manual", which provides
experienced users with detailed descriptions of all the functions.
Setpoint addition
Description
The supplementary setpoint can be used to enter correction values from higher-level closed-
loop controls. This can be implemented using the summing point of the main/supplementary
setpoint in the setpoint channel. Both variables are imported simultaneously via two separate
or one setpoint source and added in the setpoint channel.
Main/added setpoint, setpoint scaling, jogging
p1070
p1071
r1073
p1075
p1076
plementary setpoint scaling
r1077
Supplementary setpoint effective
r1078