Functions, monitoring, and protective functions
9.4 Monitoring and protective functions
Converter cabinet units
586 Operating Instructions, 07/2016, A5E03347396A
9.4.5.7
Function diagram
FP 8016
Thermal monitoring motor
FP 8017
Thermal motor models
FP 9576
TM31 - temperature evaluation (KTY/PTC)
9.4.5.8
Parameters
Temperature sensor evaluation
•
r0035
CO: Motor temperature
•
p0600
Motor tempe
rature sensor for monitoring
•
p0601
Motor temperature sensor type
•
p0603
Motor temperature signal source
•
p0604
Motor overtemperature fault threshold
•
p0605
Motor overtemperature fault threshold
•
p0606
Motor overtemperature timer
•
p0607
Temperature sensor
fault timer
•
p0610
Motor overtemperature response
•
p0614
Thermal resistance adaptation reduction factor
•
p0624
Motor temperature offset PT100
•
p4100
TM31 temperature evaluation sensor type
•
r4105
CO: TM31 temperature evaluation actual value
Thermal motor model 1 (for permanent-magnet synchronous machines)
•
r0034
CO: Motor utilization
•
r0068[0]
CO: Absolute value of actual current, unsmoothed
•
p0318
Motor stall current
•
p0605
Motor overtemperature fault threshold
•
p0610
Motor overtemperature response
•
p0611
I2t motor model thermal time constant
•
p0612
Thermal motor model configuration
•
p0613
Mot_temp_mod 1/3 ambient temperature
•
p0615
I2t motor model fault threshold
•
p0625
Motor ambient temperature
•
p0627
Motor overtemperature, stator winding
•
p0632
Mot_temp
_mod stator winding temperature
•
p5350
Mot_temp_mod 1/3 zero speed boost factor
•
p5390
Mot_temp_mod 1/3 alarm threshold
•
p5391
Mot_temp_mod 1/3 fault threshold

Table of Contents