EasyManua.ls Logo

Siemens SINAMICS G150 - Internal Armature Short-Circuit Braking

Siemens SINAMICS G150
680 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functions, monitoring, and protective functions
9.2 Drive functions
Converter cabinet units
Operating Instructions, 07/2016, A5E03347396A
507
Function diagram
FP 7014
Technology functions - External armature short circuit
Parameters
•
p0300:
Mot type selection
•
p1230
BI: Armature short
-circuit/DC braking activation
•
p1231
Armatu
re short-circuit/DC braking configuration
•
1: External armature short-circuit with contactor feedback signal
•
2: External armature short-circuit without contactor feedback signal
•
p1235
BI: External armature short
-circuit, contactor feedback signal
•
p1236
Ex
ternal armature short-circuit, contactor feedback signal monitoring time
•
p1237
External armature short
-circuit, delay time when opening
•
r1238
CO: External armature short
-circuit state
•
r1239
CO/BO: Armature short
-circuit/DC braking status word
9.2.9.3
Internal armature short-circuit braking
Description
Internal armature short-circuit braking is only available for synchronous motors. It is used
preferably when braking in a hazardous situation, if controlled braking via the drive is no
longer possible (for example, in the event of a power failure, an EMERGENCY OFF, etc.) or
if no regenerative infeed is used. In this case, the motor stator windings are short-circuited
via a half-bridge in the power unit. This means that an additional resistance is inserted in the
motor circuit that supports reducing the kinetic energy of the motor.
The internal armature short circuit is configured via p1231 = 4 and activated via p1230. It is
initiated when the pulses are canceled.
A prerequisite for the use of the internal armature short circuit is the use of a permanent-
magnet synchronous motor (p0300 = 2xx).
DANGER
Danger to life due to electric shock for armature short-circuit braking
When the armature short-circuit is active, after the pulses have been cancelled all the motor
terminals are at half the DC link potential.
Contact with live parts can result in death or serious injury.
• Observe the general safety instructions.