Functions, monitoring, and protective functions
9.2 Drive functions
Converter cabinet units
Operating Instructions, 07/2016, A5E03347396A
483
9.2.1.4
Parameters
r0047
Motor data
identification and speed controller optimization
p1300
Open
-loop/closed-loop control operating mode
p1900
Motor data identification and rotating measurement
p1909
Motor data identification, control word
p1910
Motor data identification selection
p1959
Rotating measurement configuration
p1960
Rotating measurement selection
p1961
Saturation characteristic speed to determine
p1965
Speed controller optimization speed
p1967
Speed controller optimization dynamic factor
r1968
Speed controller optimization
actual dynamic factor
r1973
Rotating measurement encoder test pulse number determined
p1980
Pole position identification procedure
r3925
Identification final display
r3927
Motor data identification, control word
r3928
Rotating measurement configurati
on
9.2.2
Efficiency optimization
Description
The following can be achieved when optimizing efficiency using p1580:
Lower motor losses in the partial load range
Minimization of noise in the motor

Table of Contents

Other manuals for Siemens SINAMICS G150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G150 and is the answer not in the manual?

Siemens SINAMICS G150 Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G150
CategoryMedia Converter
LanguageEnglish

Related product manuals