Operation
6.3 Basic information about the drive system
Converter cabinet units
Operating Instructions, 07/2016, A5E03347396A
273
Figure 6-8 Connection of OFF3 to several drives (example)
Analysis of BICO interconnections
The following parameters exist for the analysis of existing BICO interconnections:
r9481
Number of BICO interconnections
r9482[0...n]
BICO interconnections BI/CI parameters
r9483[0...n]
BICO interconnections BO/CO parameters
p9494
BICO interconnections, search signal source
p9495
BICO interconnections, search signal
source number
p9496
BICO interconnections, search signal source first index
BICO interconnections to other drives
The following parameters are available for BICO interconnections to other drives:
r9490
Number of BICO interconnections to other drives
r9491[0...9]
BI/CI of BICO interconnections to other drives
r9492[0...9]
BO/CO of BICO interconnections to other drives
p9493[0...9]
Reset BICO interconnections to other drives
Binector-connector converters and connector-binector converters
Binector-connector converter
Several digital signals are converted to a 32-bit integer double word or to a 16-bit integer
word.
p2080[0...15] BI: PROFIdrive PZD send bit-serial