EasyManua.ls Logo

Siemens SINAMICS G150 - Page 335

Siemens SINAMICS G150
680 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
6.7 Communication according to PROFIdrive
Converter cabinet units
Operating Instructions, 07/2016, A5E03347396A
335
Create request
Table 6- 24 Parameter request
Parameter request
Offset
Request header Request reference = 40 hex Request ID = 02 hex 0 + 1
Axis = 02 hex Number of parameters =
04 hex
2 + 3
1st parameter
address
Attribute = 10 hex Number of elements = 01 hex 4 + 5
Parameter no. = 1055 dec 6
Subindex = 0 dec 8
2nd parameter
address
Attribute = 10 hex Number of elements = 01 hex 10 + 11
Parameter no. = 1056 dec 12
Subindex = 0 dec 14
3rd parameter
address
Attribute = 10 hex Number of elements = 01 hex 16 + 17
Parameter no. = 1058 dec 18
Subindex = 0 dec 20
4th parameter
address
Attribute = 10 hex Number of elements = 01 hex 22 + 23
Parameter no. = 1059 dec 24
Subindex = 0 dec 26
1st parameter
value(s)
Format = 07 hex Number of values = 01 hex 28 + 29
Value = 02D2 hex 30
Value = 0404 hex 32
2nd parameter
value(s)
Format = 07 hex Number of values = 01 hex 34 + 35
Value = 02D2 hex 36
Value = 0405 hex 38
3rd parameter
value(s)
Format = 08 hex Number of values = 01 hex 40 + 41
Value = 4396 hex 42
Value = 0000 hex 44
4th parameter
value(s)
Format = 08 hex Number of values = 01 hex 46 + 47
Value = 4416 hex 48
Value = 0000 hex 50
Information about the parameter request:
Request reference:
The value is selected at random from the valid value range. The request reference
establishes the relationship between request and response.
Request identifier:
02 hex → This identifier is required for a write request.
Axis:
02 hex → The parameters are written to drive 2.
Number of parameters:
04 hex → The multi-parameter request comprises 4 individual parameter requests.

Table of Contents

Other manuals for Siemens SINAMICS G150

Related product manuals