Functions, monitoring, and protective functions
9.2 Drive functions
Converter cabinet units
510 Operating Instructions, 07/2016, A5E03347396A
Activation via p1231 = 5 (DC braking for OFF1/OFF3)
DC braking is activated with OFF1 or OFF3
● If the motor speed ≥ p1234, the motor is braked down to p1234. As soon as the motor
speed is < p1234, the pulses are disabled and the motor is demagnetized.
● If the motor speed at OFF1/OFF3 is already < p1234, the pulses are immediately
inhibited and the motor is demagnetized.
DC braking is activated for the period set in p1233 (DC braking duration), then switched off.
When OFF1/OFF3 is prematurely canceled, then normal operation is resumed.
DC braking as emergency braking of a fault response remains active.
Technology functions - DC braking
p0300:
p0491
Motor encoder fault response: ENCODER
p1226
Threshold for standstill detection
p1230
-circuit/DC braking activation
p1231
-circuit/DC braking configuration
4: Internal armature short-circuit/DC braking
5: DC braking OFF1/OFF3
14: DC braking below starting speed
p1232
DC braking, braking current
p1233
p1234
Speed at the start of DC braking
r1239
-circuit/DC braking status word
p2100
Changing the fault reaction, fault number
p2101
Changing the fault reaction, reaction