Electrical installation
4.6 Electrical connection
Converter cabinet units
Operating Instructions, 07/2016, A5E03347396A
81
Figure 4-8 DRIVE-CLiQ cable routing
Connecting the DRIVE-CLiQ cables
The connecting cables are located in the Line Connection Module (+H.A25) in the right
transport unit. They must be connected to the appropriate DRIVE-CLiQ socket –X400 of the
Motor Modules (+H.A49) in the left transport unit or to DRIVE-CLiQ socket –X400 of the
Basic Line Modules (+H.A29) in the left transport unit as marked on the DRIVE-CLiQ cables.
The cables must be routed so that power cables cannot cause interference on the DRIVE-
CLiQ connection.