Machine and Setting Data
D.1 Machine/Setting data
04.07
D-217
© Siemens AG 2007 All rights reserved
SINUMERIK 802D sl/840D/840D sl/840Di/840Di sl/810D ISO Milling (PGM) -- 04.07 Edition
10704 DRYRUN_MASK
MD number Activating dry run feed
Default setting: Minimum input limit: -- Maximum input limit: --
Changes effective after: Protection level: Unit: --
Data type: BYTE Applies with effect from SW version:
Meaning: DRYRUN_MASK == 0
Dryrun must only be activated or deactivated at the end of a block.
DRYRUN_MASK == 1
Dry run feed may be activated or deactivated even during program execution
Note:
Once dry run feed has been activated, the axes are stopped for the duration of
the reorganization.
DRYRUN_MASK == 2
Dryrun can be activated or deactivated in any phase and the axes are not stopped.
Note:
However, the function is only effective upon using a block which comes ”later”
in the program run. The function takes effect on the next (implicit) Stop Reset.
This MD cannot SINUMERIK 802D sl.
10706 SLASH_MASK
MD number Activating the block skip function
Default setting: Minimum input limit: -- Maximum input limit: --
Changes effective after: Protection level: Unit: --
Data type: BYTE Applies with effect from SW version:
Meaning: SLASH_MASK == 0
The block skip function can only be switched over at the end of a block.
SLASH_MASK == 1
When SLASH_MASK == 1 the block skip function may be activated even during program
execution.
Note:
Once block skip has been activated, the axes are stopped for the duration of
the reorganization.
SLASH_MASK == 2
Block switchover is possible in any phase.
Note:
However, the function is only effective upon using a block which comes ”later”
in the program run. The function takes effect on the next (implicit) Stop Reset.
This MD cannot SINUMERIK 802D sl.