Machine and Setting Data
D.3 Axis-specific setting data
04.07
D-236
© Siemens AG 2007 All rights reserved
SINUMERIK 802D sl/840D/840D sl/840Di/840Di sl/810D ISO Milling (PGM) -- 04.07 Edition
D.3 Axis-specific setting data
43120 DEFAULT_SCALE_FACTOR_AXIS
MD number Default axial scale factor for G51 active
Default setting: 1 Minimum input limit: --99999999 Maximum input limit: 99999999
Changes effective IMMEDIATELY Protection level: 7/7 Unit: --
Data type: DWORD Applies with effect from SW version: 5.2
Meaning: This machine data applies in combination with external programming languages. It is
effective with $MN_MM_EXTERN_LANGUAGE = 1.
If no axial scale factor I, J or K is programmed in the G51 block,
DEFAULT_SCALEFACTOR_AXIS is effective.
This MD is valid only if MD AXES_SCALE_ENABLE is set.
43240 M19_SPOS
MD number Position of spindle (degree) when commanding M19
Default setting: 0 Minimum input limit: --359.999 Maximum input limit: 359.999
Changes effective IMMEDIATELY Protection level: 7/7 Unit: --
Data type: DOUBLE Applies with effect from SW version: 5.2
Meaning: Das Settingdatum ist auch im Siemens--Mode wirksam.

Table of Contents

Other manuals for Siemens SINUMERIK 802D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802D sl and is the answer not in the manual?

Siemens SINUMERIK 802D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802D sl
CategoryController
LanguageEnglish

Related product manuals