Machine and Setting Data
D.2 Channel-specific machine data
04.07
D-228
© Siemens AG 2007 All rights reserved
SINUMERIK 802D sl/840D/840D sl/840Di/840Di sl/810D ISO Milling (PGM) -- 04.07 Edition
20150 GCODE_RESET_VALUES
MD Number Initial setting of G groups
Default setting: 2, 0, 0, 1, 0, ... Minimum input limit: -- Maximum input limit: --
Changes effective after RESET Protection level: 2/7 Unit: --
Data type: BYTE Applies with effect from SW version:
Bedeutung: Definition of G codes which become active on runup and reset or at part program end.
The index of the G codes in the respective groups must be programmed as the default
value.
Title Group Default
GCODE_RESET_VALUES[0] 1 2 (G01)
GCODE_RESET_VALUES[1] 2 0 (inaktiv)
GCODE_RESET_VALUES[2] 3 0 (inaktiv)
GCODE_RESET_VALUES[3] 4 1 (START FIFO)
GCODE_RESET_VALUES[4] 5 0 (inaktiv)
GCODE_RESET_VALUES[5] 6 1 (G17) bei Fräsen
GCODE_RESET_VALUES[6] 7 1 (G40)
GCODE_RESET_VALUES[7] 8 1 (G500)
GCODE_RESET_VALUES[8] 9 0 (inaktiv)
GCODE_RESET_VALUES[9] 10 1 (G60)
GCODE_RESET_VALUES[10] 11 0 (inaktiv)
GCODE_RESET_VALUES[11] 12 1 (G601)
GCODE_RESET_VALUES[12] 13 2 (G71)
GCODE_RESET_VALUES[13] 14 1 (G90)
GCODE_RESET_VALUES[14] 15 2 (G94)
GCODE_RESET_VALUES[15] 16 1 (CFC)
...