Machine and Setting Data
D.2 Channel-specific machine data
04.07
D-228
© Siemens AG 2007 All rights reserved
SINUMERIK 802D sl/840D/840D sl/840Di/840Di sl/810D ISO Milling (PGM) -- 04.07 Edition
20150 GCODE_RESET_VALUES
MD Number Initial setting of G groups
Default setting: 2, 0, 0, 1, 0, ... Minimum input limit: -- Maximum input limit: --
Changes effective after RESET Protection level: 2/7 Unit: --
Data type: BYTE Applies with effect from SW version:
Bedeutung: Definition of G codes which become active on runup and reset or at part program end.
The index of the G codes in the respective groups must be programmed as the default
value.
Title Group Default
GCODE_RESET_VALUES[0] 1 2 (G01)
GCODE_RESET_VALUES[1] 2 0 (inaktiv)
GCODE_RESET_VALUES[2] 3 0 (inaktiv)
GCODE_RESET_VALUES[3] 4 1 (START FIFO)
GCODE_RESET_VALUES[4] 5 0 (inaktiv)
GCODE_RESET_VALUES[5] 6 1 (G17) bei Fräsen
GCODE_RESET_VALUES[6] 7 1 (G40)
GCODE_RESET_VALUES[7] 8 1 (G500)
GCODE_RESET_VALUES[8] 9 0 (inaktiv)
GCODE_RESET_VALUES[9] 10 1 (G60)
GCODE_RESET_VALUES[10] 11 0 (inaktiv)
GCODE_RESET_VALUES[11] 12 1 (G601)
GCODE_RESET_VALUES[12] 13 2 (G71)
GCODE_RESET_VALUES[13] 14 1 (G90)
GCODE_RESET_VALUES[14] 15 2 (G94)
GCODE_RESET_VALUES[15] 16 1 (CFC)
...

Table of Contents

Other manuals for Siemens SINUMERIK 802D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802D sl and is the answer not in the manual?

Siemens SINUMERIK 802D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802D sl
CategoryController
LanguageEnglish

Related product manuals