Machine and Setting Data
D.2 Channel-specific machine data
04.07
D-230
© Siemens AG 2007 All rights reserved
SINUMERIK 802D sl/840D/840D sl/840Di/840Di sl/810D ISO Milling (PGM) -- 04.07 Edition
20380 TOOL_CORR_MODE_G43/G44
MD number Processing of prog. length offsets G43/G44
Default setting: 0 Minimum input limit: 1 Maximum input limit: 2
Changes effective after RESET Protection level: 2/7 Unit: --
Data type: BYTE Applies with effect from SW version: 5.2
Meaning: The machine data is only effective if MD EXTERN_CNC_LANGUAGE = 1.
When G43/G44 is active, it determines how length offsets programmed with H are pro--ces-
sed.
0: mode A
The tool length H always acts on the Z axis,
independent of the current plane.
1: mode B
The tool length H acts on one of the three geometry axes
depending on the active plane:
G17 on the 3rd geometry axis (usually Z)
G18 on the 2nd geometry axis (usually Y)
G19 on the 1st geometry axis (usually X)
By multiple programming, length offsets can be established in all three geometrical axes in
this mode, i.e. by activating an offset, the existing length offset of another axis will not be
cancelled.
2: mode C
The tool length offset becomes valid in the axis programmed together with the
H code regardless of the selected plane. Further, the behaviour is as discribed
under mode B.
This MD cannot SINUMERIK 802D sl.
20382 TOOL_CORR_MOVE_MODE
MD number Traversing the tool length offset
Default setting: F ALSE Minimum input limit: -- Maximum input limit: --
Changes effective after RESET Protection level: 2/7 Unit: --
Data type: BOOLEAN Applies with effect from SW version: 5.2
Meaning: The machine data determines how the tool length offsets are applied.
FALSE: A tool length offset is only applied if the associated axis was programmed.
(Same behaviour as in previous SW versions)
TRUE: Tool length offsets are always applied, regardless of whether the associated
axes were programmed.
This MD cannot SINUMERIK 802D sl.
20732 EXTERN_G0_LINEAR_MODE
MD number Rapid traverse interpolation selection
Default setting: 1 Minimum input limit: 0 Maximum input limit: 1
Changes effective after POWER ON Protection level: 2/4 Unit: --
Data type: BOOLEAN Applies with effect from SW version:
Meaning: This MD determines G00 interpolation behaviour.
0: axes move like positioning axes
1: linear interpolation