Redefinition (REDEF) of system and user data
Access rights (APR.../APW...) can be redefined for the following data:
● System data
– Machine data
Note
Redefinition of reading rights of machine data
The protection level for reading machine data can only be set with keyword APR for the
part program and OPI.
The keywords APRP and APRB are not supported by the redefinition of the reading
rights, and result in alarm 12490 "Access right APRP/APRB <protection level> was not
set".
– Setting data
– System variable
– Process data
– Magazine data
– Tool data
● User data
– R parameters
– Synchronized action variables ($AC_MARKER, $AC_PARAM, $AC_TIMER)
– Synchronized action GUD (SYG_xy[ ], where x=R, I, B, A, C, S and y=S, M, U, 4 to 9)
– EPS parameters
– Tool data OEM
– Magazine data OEM
– Global user variables (GUD)
Note
During redefinition the access right can be freely assigned to a variable between the
lowest protection level 7 and the dedicated protection level, e.g. 1 (machine
manufacturer).
Redefinition (REDEF) of NC language commands
The access or execution right (APX) can be redefined for the following NC language
commands:
● G commands / preparatory functions (Page 170)
● Predefined functions (Page 1290)
● Predefined subprogram calls
Work preparation
3.1 Flexible NC programming
NC programming
Programming Manual, 12/2019, 6FC5398-2EP40-0BA0 413