No. Screen
form pa‐
rameter
Cycle pa‐
rameter
Meaning
22 _AMODE Alternative mode
Val‐
ues:
UNITS: Measuring the tool offset for radius
1 = No
2 = Yes
TENS: Direction of the tool offset when measuring the radius in the 3rd axis of the
plane (for G17 Z)
1 = Positive
2 = Negative
HUNDREDS: Tool offset when measuring the length or when calibrating the probe
in the 3rd axis
0 = Compatibility, auto
1 = No
2 = Yes
THOUSANDS: Direction of the tool offset when measuring the length in the offset
axis (see S_MA HUNDREDS)
1 = Positive
2 = Negative
1)
All default values = 0 or marked as default=x
2)
Display depends on the general SD54762 MEA_FUNCTION_MASK_TOOL
3)
Only for offset in tool and dimensional tolerance "Yes", otherwise parameter = 0
4)
For automatic measurement (S_MVAR=1x00xx), no display of measuring axis, offset axis ⇒ S_MA=0.
3.25.3.16 CYCLE150 measuring cycle parameters
PROC CYCLE150(INT S_PICT,INT S_PROT,STRING[160] S_PATH) SAVE
ACTBLOCNO DISPLOF
Table 3-23 CYCLE150 call parameters
No. Screen pa‐
rameters
Cycle pa‐
rameters
Meaning
1 Measuring
result
screen
S_PICT Select result display (default = 0)
Values: UNITS:
0 = Measuring result screen OFF
1 = Measuring result screen ON
Tens: Select display mode (values as for SD55613)
1 = Display measuring result screen - automatically deselect after 8 s
3 = Display measuring result screen - acknowledge using NC Start
4 = Display measuring result screen - only for alarms (61303 ... 61306)
2 S_PROT Select logging (default = 0)
Work preparation
3.25 Programming cycles externally
NC programming
1194 Programming Manual, 12/2019, 6FC5398-2EP40-0BA0