Examples:
Passive file system or GDIR:
NC notation: _N_WKS_DIR/_N_MYNCPROGS_WPD/...
EES notation: WKS.DIR/MYPROGS.WPD/...
External program memory:
/abc
/ab_c.def
/ab c1.def
/a b c .d11
/abc.def/ghi.klm
File name
The following rules apply to the file names:
Only for addressing in NC notation do file names begin with the domain identification "_N_".
The next two characters should be either two letters or an underscore followed by a letter.
Note
If this condition is satisfied, then an NC program can be called as subprogram from another
program just by specifying the program name. However, if the program name starts with
digits, the subprogram call is then only possible via the CALL statement.
The following characters can be any combination of letters, digits and "_".
File extension:
The file extension must consist of three letters/digits.
Note
Permitted file extensions in the passive file system, see "Program memory in the NCK
(Page 551)".
They are separated with "_" (NC notation) or "." (EES notation) from the file names.
Examples:
Passive file system or GDIR:
NC notation: _N_SUB1_SPF
EES notation: SUB1.SPF
External program memory:
Part 1
_Part1
Part_1.spf
Part1.mpf
Work preparation
3.4 File and Program Management
NC programming
558 Programming Manual, 12/2019, 6FC5398-2EP40-0BA0

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals