You can save the NC and PLC data of the volatile memory to the permanent memory of the control system.
Note
After changing important data, it is recommended to carry out an internal data backup immediately.
Backing up data internally
Prerequisite:
● A valid system password has been set on the control system.
● There is no program currently being executed.
Proceed through the following steps to save data:
Select the system data operating area.
Press this softkey to open the window for data saving.
Press this softkey to start saving. Do not carry out any operator actions while the data bac
k-
Loading internally backed up data
There are two methods to load the saved data.
Press this key while the con
trol system is booting.
Use the cursor keys to select "Reload saved user data" in the setup menu.
Press this key to confirm.
Select the system data operating area.
ss this softkey.
Enter the NC startup screen.
Use the cursor keys to select the third star
tup mode as follows: