A.8 Information List
393
7UM61 Manual
C53000-G1176-C127-3
162 Failure: Current Summation (Fail-
ure Σ I)
Measurem.Superv AM ON
OFF
* * LED BO 135 182 1 Yes
163 Failure: Current Balance (Fail I
balance)
Measurem.Superv AM ON
OFF
* * LED BO 135 183 1 Yes
164 Failure: General Voltage Supervi-
sion (Fail U Superv.)
Measurem.Superv AM ON
OFF
**LEDBO70331Yes
165 Failure: Voltage Summation
Phase-Earth (Fail Σ U Ph-E)
Measurem.Superv AM ON
OFF
* * LED BO 135 184 1 Yes
167 Failure: Voltage Balance (Fail U
balance)
Measurem.Superv AM ON
OFF
* * LED BO 135 186 1 Yes
171 Failure: Phase Sequence (Fail
Ph. Seq.)
Measurem.Superv AM ON
OFF
**LEDBO70351Yes
175 Failure: Phase Sequence Current
(Fail Ph. Seq. I)
Measurem.Superv AM ON
OFF
* * LED BO 135 191 1 Yes
176 Failure: Phase Sequence Voltage
(Fail Ph. Seq. U)
Measurem.Superv AM ON
OFF
* * LED BO 135 192 1 Yes
177 Failure: Battery empty (Fail Bat-
tery)
Device AM ON
OFF
**LEDBO
181 Error: A/D converter (Error A/D-
conv.)
Device AM ON
OFF
**LEDBO
183 Error Board 1 (Error Board 1) Device AM ON
OFF
**LEDBO
184 Error Board 2 (Error Board 2) Device AM ON
OFF
**LEDBO
185 Error Board 3 (Error Board 3) Device AM ON
OFF
**LEDBO
186 Error Board 4 (Error Board 4) Device AM ON
OFF
**LEDBO
187 Error Board 5 (Error Board 5) Device AM ON
OFF
**LEDBO
188 Error Board 6 (Error Board 6) Device AM ON
OFF
**LEDBO
189 Error Board 7 (Error Board 7) Device AM ON
OFF
**LEDBO
190 Error Board 0 (Error Board 0) Device AM ON
OFF
**LEDBO
191 Error: Offset (Error Offset) Device AM ON
OFF
**LEDBO
192 Error:1A/5Ajumper different from
setting (Error1A/5Awrong)
Device AM ON
OFF
**LEDBO
193 Alarm: NO calibration data avail-
able (Alarm NO calibr)
Device AM ON
OFF
**LEDBO
194 Error: Neutral CT different from
MLFB (Error neutralCT)
Device AM ON
OFF
**LEDBO
197 Measurement Supervision is
switched OFF (MeasSup OFF)
Measurem.Superv AM ON
OFF
* * LED BO 135 197 1 Yes
203 Waveform data deleted (Wave.
deleted)
Osc. Fault Rec. AM_
W
ON * * LED BO 135 203 1 No
264 Failure: RTD-Box 1 (Fail: RTD-
Box 1)
Device AM ON
OFF
* * LED BO 135 208 1 Yes
267 Failure: RTD-Box 2 (Fail: RTD-
Box 2)
Device AM ON
OFF
* * LED BO 135 209 1 Yes
272 Set Point Operating Hours (SP.
Op Hours>)
SetPoint(Stat) AM ON
OFF
* * LED BO 135 229 1 Yes
284 Set Point I< alarm (SP. I<) Set Points(MV) AM * * * LED BO 135 244 1 Yes
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Typ e
Information Number
Data Unit
General Interrogation