Accessories
9.30 Terminal cover for cable lug connection and busbar connection
SIRIUS - SIRIUS 3RT Contactors/Contactor assemblies
Manual, 09/2017, A5E03656507120A/RS-AE/006
441
9.30.2
Mounting
Mounting the terminal cover for cable lug connection and busbar connection
The diagram below uses the 3RT2.4 contactor size S3 as an example of mounting the
3RT1946-4EA1 terminal cover for cable lug connection and busbar connection.
Position the screwdriver on the terminal support, as shown in the figure, in the middle between
the contactor and the removable box terminal block.
Carefully lever the detachable box terminal block from the contactor.
Detach the box terminal block from the contactor in the upward direction.