PROFIBUS DP Communication Module
SIRIUS 3RW44 manual
GWA 4NEB 535 2195-02 DS 06
8-11
The next step is to set the desired station address for the 3RW44 as a
PROFIBUS slave.
In this example, the station address is set to "23".
Notice
If the parameter "Parameters disabled CPU/Master" is set to "Off" (factory setting), then
the parameters set on the soft starter will be overwritten with the values stored in the GSD
file or in the OM when the bus is started. If this is not desired, the parameter must be set
to "On".
Fieldbus
select
1
change
interface
On
ESC OK
Group diagnosis
select
2
change
Disable
ESC OK
Response to
3
change
Substitute value
ESC OK
CPU master stop
Station address
select
execute
23
Station address
select
4
change
23
ESC OK
ESC OK
Station address
select
execute
126
ESC OK
Station address
select
4
change
126
ESC
OK
Adjustable
from ... to
1... 126
Parameterization options
On, Off
Disable, enable
Substitute value, last value
Baud rate
5
12,000 kBd
Substitute value
select
6
select
Parameters
select
7
change
Off
ESC OK
disable CPU/Master
ESC OK
ESC OK