8.12.4 Data Set 73 Log List - Reading the Trippings
Table 8-20: Data set 73 - log list - reading the trippings
This data set can record 21 entries. When all spaces are filled, the first entry is
overwritten.
Note
The latest entry is entered at the end of the data set. The remaining entries are
moved up by one entry.
Byte Meaning Value range Increment Comment
0 - 3 Operating hours - device 1 ... 2
32
s 1 second
Oldest entry
4 - 5 ID number of the device
error
0 ...
± 32,767 1
6 - 9 Operating hours - device 1 ... 2
32
s 1 second Second oldest
entry
10 - 11 ID number of the device
error
0 ...
± 32,767 1
etc.
120 - 123 Operating hours - device 1 ... 2
32
s 1 second Last,
newest entry
124 - 125 ID number of the tripping 0 ...
± 32,767 1