Functional safety
8.7 PROFIsafe
SITRANS P DS III with PROFIBUS PA
144 Operating Instructions, 06/2013, A5E00053276-07
8.7.6
Write protection
8.7.6.1
Overview
Write protection
The following write-protection options are available:
Lock or unlock device
The dialog box shows the current write protection. If you have activated write protection
with PIN, you can lock or unlock the device with the PIN here.
Default PIN: 2457
Change stored PIN
The dialog box shows the current write protection. In addition, you enter your desired PIN
here.
Enter Super PIN
If you have forgotten your PIN, it is possible to deactivate the write protection by entering
the super PIN. The device resets the PIN to the default value.
Super PIN: G73KMQ2W
See also
Activate write protection using PIN in SIMATIC PDM (Page 145)
Activate and parameterize PROFIsafe with SIMATIC PDM (Page 146)
Disable write protection using PIN in SIMATIC PDM (Page 155)

Table of Contents

Other manuals for Siemens SITRANS P DS III

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SITRANS P DS III and is the answer not in the manual?

Siemens SITRANS P DS III Specifications

General IconGeneral
TypePressure Transmitter
CommunicationHART, PROFIBUS PA, FOUNDATION Fieldbus
Housing materialAluminum or Stainless Steel
Measured variablePressure
Output signal4...20 mA HART, PROFIBUS PA, Foundation Fieldbus
Ambient temperature range-40 to +85 °C
Power supply10.5...45 V DC
Protection classIP66, IP67
Process connectionVarious