Installing / mounting
4.2 Disassembly
SITRANS P DS III with PROFIBUS PA
44 Operating Instructions, 06/2013, A5E00053276-07
Loss of degree of protection
Damage to device if the enclosure is open or not properly closed. The degree of protection
specified on the nameplate or in Chapter "Technical data (Page 191)" is no longer
guaranteed.
• Make sure that the device is securely closed.
PROFIBUS assembly guidelines (Page 66)
The following dangers may result through incorrect disassembly:
- Injury through electric shock
- Danger through emerging media when connected to the process
- Danger of explosion in hazardous area
In order to disassemble correctly, observe the following:
• Before starting work, make sure that you have switched off all physical variables such
as pressure, temperature, electricity etc. or that they have a harmless value.
• If the device contains dangerous media, it must be emptied prior to disassembly. Make
sure that no environmentally hazardous media are released.
• Secure the remaining connections so that no damage can result if the process is started
unintentionally.