Functional safety
8.7 PROFIsafe
SITRANS P DS III with PROFIBUS PA
Operating Instructions, 06/2013, A5E00053276-07
155
8.7.8.3
Disable write protection using PIN in SIMATIC PDM
Procedure
1. In the "Device" menu, select the "Write protection" command.
2. Click on the "OFF" button.
3. Enter the user-defined PIN, the default PIN, or the super PIN.
See also
Overview (Page 144)
8.7.9
Replacing a device
Replacing a PROFIsafe device with firmware <= 0301.02.02 or a PROFIBUS device with a
PROFIsafe device with firmware 0301.02.03 or higher
When shipped, PROFIsafe is disabled on the replacement device.
Requirement
Import the PROFIsafe EDD as of version 01.02.03 to the device catalog of SIMATIC PDM.
Process
1. Replace the device.
2. Configure the device. You have two options:
Making settings locally
Host system
The EDD of the new device must be reassigned to that of the replaced PDM object. Making
the reassignment in the "Process Devices - Network View" of the SIMATIC Manager.
8.7.9.1
Making settings locally
Procedure
1. Set mode 16.
2. Set the device mode [129] with the [↑] and [↓] keys.
3. Save with the [M] key.