Technical data
13.5 Operating conditions
SITRANS P DS III with PROFIBUS PA
Operating Instructions, 06/2013, A5E00053276-07
209
Rated conditions DS III with PMC connection
Electromagnetic compatibility
Interference emission and
interference immunity
In accordance with EN 61326 and NAMUR NE 21
Process medium conditions
Process temperature
-40 … +100 °C (-40 … +212 °F)
Rated conditions for absolute pressure (from the differential pressure series), differential pressure and flow rate
Installation conditions
Installation instruction
any
Ambient conditions
Ambient temperature
Note
Observe the temperature class in hazardous areas.
Measuring cell with silicone oil
filling
-40 … +85 °C (-40 … +185 °F)
Measuring cell
30 bar (435 psi)
-20 … +85 °C (-4 … +185 °F)
With flow: -20 … +85 °C (-4 … +185 °F)
Measuring cell with inert liquid
-20 … +85 °C (-4 … +185 °F)
Display
-30 … +85 °C (-22 … +185 °F)
Storage temperature
-50 … +85 °C (-58 … +185 °F)
Climate class
Condensation
Permitted
Degree of protection in
accordance with EN 60529
IP65, IP68
Degree of protection in
accordance with NEMA 250
NEMA 4X
Electromagnetic compatibility
Interference emission and
interference immunity
In accordance with EN 61326 and NAMUR NE 21
Process medium conditions
Process temperature
Measuring cell with silicone oil
filling
-40 … +100 °C (-40 … +212 °F)
Measuring cell
30 bar (435 psi)
-20 … +85 °C (-4 … +185 °F)
Measuring cell with inert liquid -20 … +100 °C (-4 … +212 °F)
Measuring cell
30 bar (435 psi)
-20 … +85 °C (-4 … +185 °F)