Copyright Silca 2004 105
Operating Manual - English IDEA
If this is not the case, e.g. X = 17,40 and Y = 11,40 proceed as follows:
Choose 4 “Calibrations” from the main menu and press
ENTER.
Choose 1 “Clamps” and press ENTER.
Choose 1 “S1 - Rotating Jaw” and press ENTER.
Clamp: S1 - K1 = unit comprising clamp S1 and interchangeable tailstock K1.
Press [SHIFT + ENTER]
(SHIFT+ENTER = to go to the other interchangeable tailstock used with clamp S1, if applicable).
Digit the corrections required for axis X and axis Y (bit 1 = Y1 / bit 2 = Y2).
Example:
Position the pointer at the side of the parameter to be edited with the arrow keys or [ENTER] and use the
following keys to edit the parameters:
SHIFT + [arrow up]:increases the value within + 300 hundredths of a mm or hundredths of a degree (axis B)
+ 20 cent. mm X/Y1/Y2
SHIFT + [arrow down]: decreases the value within - 300 hundredths of a mm or hundredths of a degree (axis
B) - 20 cent. mm X/Y1/Y2
CLEAR = to zero the value
[ENTER] = in the last field to quit the window so that the query Save? appears for the edited data.
[START] = press START to begin the automatic gauging procedure or the CLAMP-TAILSTOCK unit.
Press ENTER
ATTENTION: if [STOP] is pressed the new measurements are not saved; the previous gauging values therefore
remain valid.
Press ENTER to confirm the data.
4 - Calibration
5 - Maintenance
6 - Options
1 - Clamps
2 - Cutters
3 - Adapters
Clamps
1: S1 - Rotating Jaw
2: S100 - Reading Jaw
Clamp: S1 – K1 >>
Adjustments: B=+000
X= +10 Y1= -15 Y2= +00
To calibrate (START)
Clamp: S1 – K2
Adjustments: B=+000
X= +10 Y1= -15 Y2= +00
To calibrate (START)
Save
Adjustments?
No=STOP Yes=ENTER