40 Copyright Silca 2004
IDEA Operating Manual - English
READING SPECIAL SQUARE STEMMED FIAM KEY (WITH STEP)
Operate as follows:
1) Press the grips on the S100-B mobile clamp and remove the adapter (jaw B) (fig. 52).
2) Install jaw C so that the letter C is facing the operator (fig. 52).
3) Open the fixed clamp (A) by pressing on the grip lever (F) and fit the
E6
adapter on the S100-A clamp so
that it butts against jaw A and the initials
E6
are upwards.
4) Press on the lever grip (F1) and fit the key into its seat so that the bit is up against the fixed clamp (E6)
(fig. 53).
ATTENTION: position the key so that the highest tooth is facing left, ensuring contact with the stop (0) on the
vertical side of the tooth.
5) Release the jaw lever.
6) Press START to proceed.
7) When the reading process starts the carriage will take the key into contact with the laser beam along an
ideal path.
At the end of the cycle see the message on the display in order to continue.
Fig. 52
Fig. 53
KEY READING
Original on right
Clamp:S100 A-C Stop: 0
[START]
Reading in progress…
Data processing
in progress
Please wait…
F
E6
F1