44 Copyright Silca 2004
IDEA Operating Manual - English
- Use the arrow keys [up, down] to scroll.
- Press [SHIFT + ENTER]
Clamp: S1 - K1
= unit comprising the S1 clamp and K1 interchangeable tailstock
>>
= press [SHIFT+ENTER] to go to the other interchangeable tailstocks used with the S1 clamp, if applicable.
Clamp: S1 - K2
= unit comprising the S1 clamp and K2 interchangeable tailstock
START
= press START to begin the automatic gauging procedure for the CLAMP TAILSTOCK unit.
Template Z13
= fit in place of the cutter (fig. 61).
Template Z15
=fit on the S1-K2 clamp as if it were a key (fig. 61). Use the plate (P) as a point of reference in
position 2 with the second pin on the template up against it. Tighten the screw (W2) with the
(T4) wrench. Replace the (T4) wrench in its seat.
Fig. 61
Press START
1 - Clamps
2 - Cutter
3 - Adapter
Clamps
1 - S1 - Rotating Jaw
2 - S100 - Reading Jaw
Clamp: S1 - K1 >>
Adjustments: B=+000
X=+00 Y1=+00 Y2=+00
To calibrate [START]
Clamp: S1 – K2
Adjustments: B=+000
X=+00 Y1=+00 Y2=+00
To calibrate [START]
Clamp: S1 - K2
Install Z15 and Z13
See operating manual
[START]
Clamp: S1 - K2
Detection
In progress
W2
Z
13
P
Z15