Copyright Silca 2004 45
Operating Manual - English IDEA
Position the pointer at the side of the parameter to be edited with the arrow keys or [ENTER] and use the following keys
to edit the parameters:
[SHIFT] + [arrow up]: increases the value within
+ 300 hundredths of a mm or hundredths of a degree (axis B)
+ 20 cent.mm X/Y1/Y2
[SHIFT] + [arrow down]: decreases the value within
- 300 hundredths of a mm or hundredths of a degree (axis B)
-
20 cent.mm X/Y1/Y2
[CLEAR]: to zero the value
[ENTER]: in the last field to quit the window so that the query Save? appears for the edited data:
ATTENTION: if [STOP] is pressed the new measurements are not saved; the previous gauging values therefore
remain valid.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
OPERATION FLOW
Choose
option 0 - Copy from Original
Choose
option 7 - Rear Stop
Choose
option 1
–
Reading + Cutting
To select jaws see diagram ch. "TYPE OF KEYS" and "Choosing an adapter for READING", page 47.
Clamp: S1 – K2
Adjustments: B=+000
X=+02 Y1=+02 Y2=+04
To calibrate [START]
Save
adjustments ?
No=STOP Yes=ENTER
0 - Copy from Original
1 - Decode and Copy
2 - Insert cuts
3 - Queue from PC
SELECT TYPE OF KEY
0 - Bit stop male
1 - Bit stop female
2 - Shoulder stop
3 - Pump
4 - Square-square tip
5 - Square-round tip
6 - Square stepped tip
7 - Rear stop
8 - Rear stop french
9 - Small bit
10 - Special bit female
1 - Reading + Cutting > Select JAWS
2 - Cutting only A - E
3 - Reading only A - F
4 - Post-Reading adj. A - G
KEY READING
Original on right
Clamp.:S100 A-E Stop:0
Adapt.: E11 [START]