56 Copyright Silca 2004
IDEA Operating Manual - English
5) Fit the E10 adapter, with the key blank in the rotating clamp (S1)
from the inside, take the adapter up to the side of the self-centring
jaws (fig. 78) and slightly close the grips on the rotating clamp with
the ’T’ wrench (T4).
6) Move the rotating clamp (S1) so that the key fits into the tailstock
(K1) with the bit all the way in (fig. 79).
7) Tighten the knob (T1). Use the T wrench (T4) to tighten the screw
(V1) first, then the screw (V2) (fig. 80). Replace the ‘T’ wrench
(T4) into its seat, lower the mobile safety shield and begin the
process with START.
Fig. 78
To make further copies of the key, you can now press ENTER.
Fig. 79
Fig. 80
Cutting in progress…
Copy: 1 of: 1
Copy 1 of 1
finished
More copies ?
No=STOP Yes=ENTER
V1