51
WhentheSU90hasbeendisabledusingthisfunction,itwillstop.Thetransmission
("pinging")stops.Thecurrentechoeswillberemovedfromthepresentation.
Relatedtopics
Choosingoperatingmodeandkeytransmitparameters,page48
SelectingNormalmodetostart"pinging",page48
SelectingReplaymode,page49
SettinguptheSU90formaximumechorefreshrate
YoucansetuptheSU90totransmit(ping)asoftenaspossible.Thisgivesyouthe
maximumrefreshrate.
Context
UseTransmissionModetocontrolhowoftentheSU90
shalltransmititsenergyintothewater.Fornormal
use,chooseMaximum.IfyouchooseMaximum,the
SU90willtransmit(ping)continuouslyandasoften
aspossible.
Procedure
1OpentheOperationmenu.
2SetOperationtoNormal.
3SetTransmissionModetoMaximum.
Thetimebetweeneachping(thepingrate)dependsmainlyonthecurrentrange.
HowfastyourProcessorUnitcommunicateswithexternalperipheralsmayalso
haveaneffectonthepingrate.