EasyManua.ls Logo

Simrad SU90 - Setting up the SU90 in a Synchronized System

Simrad SU90
178 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
132
381291/C
6Setuptheinterface.
aSelecttheEthernetportorserialportyouwanttouse.
bSelectwhichprotocol(datagramsentence)youwanttouse.
cIfyouareusingaserialline,denethebaudrate.
7Atthebottomofthedialogbox,selectApplytosaveyoursettings.
8ContinueyourworkintheInstallationdialogbox,orselectOKtocloseit.
Relatedtopics
Settinguptheinterfacestoperipheraldevices,page119
SettinguptheSU90inasynchronizedsystem
IfyouwanttousetheSU90asamasterorslaveinasynchronizedsystem,youmustset
itupforsuchoperation.Todothis,youmustselectwhichcommunicationporttousefor
thesynchronizationinterface,andyoumustselecttherequestedsynchronizationmode.
Prerequisites
Thisprocedureassumesthat:
Thevesselisberthedoratsea.
YouhaveanRS2-232interfaceportonyourProcessorUnitthatallowsyoutousethe
CTS/RTSconnections.
For"slave"operation,aremotesystem(forexampleK-SyncorSimradTU40)mustbe
availabletoprovidetriggerpulses.For"master"operation,aremotehydroacoustic
system(sonar,echosounder)isconnected.Thisremotesystemmustbesetupin"slave"
mode.
Context
Whenevermorethanonehydroacousticsystemisinstalledonavessel,interferencemay
occur.Toavoidinterference,youhavetheseoptions:
Thesystemsareallconnectedtoacommonsynchronizationsystem.
Oneoftheacousticsystemsissetupas"master",andcontrolsthetransmissionson
theothersystems.
TheSU90offersfunctionalityforremotetransmitsynchronization.Itcanbesetupto
operateineitherMasterorSlavemode.
Note
WhenyouworkintheInstallationdialogbox,youmustalwaysselectApplytosavethe
changesmadeonapage.Youmustdothisbefore
youcontinueworkingonadifferent
page.