Werecommendthatyoudothistesttwice.First,dothetestwithallotherhydroacoustic
systems(echosounders,ADCP ,sonars)turnedoff.Second,dothetestwithnormal
operatingconditions.Thisallowsyoutoseehowtheotherhydroacousticsystemsaffect
theSU90operation.
Procedure
1OntheMainmenu,selectUserSettings.
aSelectSU90FactoryDefault.
bSelectActivateSelectedSetting.
cSelectOKtoapplyyourchangesandclosetheUserSettingsdialogbox.
2OntheMainmenu,setRangeto1000m.
3OpentheOperationmenu.SetTxPowertoOff.
4OpentheActivemenu.SetPulseTypetoCWMedium.
5OpentheSetupmenu.
6SelectBITEtoopenthedialogbox.
aSelectNoisetoopenthepage.
bSelectStartNoiseMeasurements.
cOntheActivemenu,changetheFrequencysettingwhileobservingthenoise
value.
dNotefrequencieswithhighnoiselevels,andtrytoavoidusingthem.
Tip
Thefactorydefaultsettingsincludeoperatingfrequency.Ifyouapplythesesettings
remembertomaketheappropriatechangesafterwards.