software.
TruePix™/Snippets BasePort: Base port number for Snippets, Snippets will be output on
a port, which is the base port plus 6. With a base port of 4000, Snippets will be on port
4006; TruePixwill be on port 4001
Water Column IP: IP address of the computer to receive water column data
Water Column BasePort: Base port number for Water Column data; Water Column data
will be output on the base port plus 5. The default base port is 4000; Water Column data
will be on UDP 4005.
Settings for Sonar 2:
All entries must be zero. Serial numbers are left blank.
Once networking is set up, Sonic Control will automatically connect upon power up; there
is no need to go back into the Network Settings