14.3 Head Commands, Binary Format
Cmd
Format
Units
Values
Description
ABS0
f32
dB/km
0 to 200
Absorption
AIB0
f32
dB
0 to 60
Acoustic image brightness
AIH0
u32
lines
0 = off
wedge radius in pixels
Acoustic imagery height. Set to
display wedge radius in pixels.
Head will return requested lines
or less, usually less. Larger
values will increase Ethernet
data rate.
AUT0
u32
Flag bits
0x00000001 = auto power on
0x00000100 = auto gain on
0x00010000 = auto range on
[7:0] auto power (not functional)
[15:8] auto gain (not functional)
[23:16] auto range
[31:24] spare
Auto power/gain work in tandem,
thus both are enabled/disabled at
same time.
BIE0
u32
0 = off
1 = on
Bathy intensity enable
BMAX
f32
metres
0 to 999
Max range filter
Head default = 999
Deprecated 12 Dec 2011, see RGB0
BMIN
f32
metres
0 to 500
Min range filter
Head default = 0
Deprecated 12 Dec 2011, see RGA0
BOS0
u32
0 = Equiangle
1 = Equidistant
Bottom sampling
DGA0
f32
metres
0 to 1200
depth gate min
DGB0
f32
metres
0 to 1200
depth gate max
DGO0
u32
0x00000000 = gates off
0x00000001 = manual gates
0x0000ww02 = auto gates
0x0000ww03 = auto gate/slope
where ww = gate width in ±
percent of depth (5% to 90%)
Depth gates control. Manual gates
mode require DGA0, DGB0, DGS0 to
be set. In auto gates mode, a
peak percentage value for gate
width must be supplied in bits
[15:8] in this command.
DGS0
f32
radians
-π/2 to +π/2
depth gate slope
DHM0
u32
0 = single head
1 = master simultaneous, dual
2 = master alternating, dual
3 = slave simultaneous, dual
4 = slave alternating, dual
Head sync mode
(single and dual head modes)
DYNA
u32
0xaabbbccc
aa = spare
bbb = slope control
ccc = depth control
ex: 0x003d0523 shows a bottom
at 5m depth which wobbles.
Generates a moving simulated
bottom for testing auto gate
features.
Three control bits:
[0:0] = magnitude (0-f)
[1:1] = magnitude (0-f)
[2:2] = rate of change (0-f)
*DYNA is also supported as an
ASCII command (enter hex digits
without the ‘0x’)
FILT
u32
0 = off
1 = range
2 = depth
3 = range & depth
FILT is deprecated. Do not use
(10 Mar 2011). Use DGO0, RGA0,
RGB0.
FIL0
u32
0 = single
1 = double
2 = quad
Bottom fill enhancement (High
Density mode.)
FRQ0
f32
Hz
200000 to 400000, and 700000
Frequency in Hz
Page 168 of 210
Version 5.0 Rev r002
Date 05-08-2014
Part No. 96000001

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sonic 2024 and is the answer not in the manual?

Sonic 2024 Specifications

General IconGeneral
BrandSonic
Model2024
CategoryMarine Equipment
LanguageEnglish

Related product manuals