Maintenance 6
Maintenance every 2000 hours
1044_606-012
Checking and cleaning the battery
WARNING
Risk of short circuit and even explosion.
Do not smoke, keep away from naked flames and
do not place metal objects on the battery.
Servicing the battery according to
the manufacturer’s instructions
WARNING
Risk of personal injury due to arcing!
– Do not reverse the battery poles or cause a short.
Insulation resistance check (earth-
ing)
The insulation of industrial trucks should have
sufficient insulation resistance. Test the truck
and battery separately.
Testing the insulation resistance of the
electrical system
Have the insulation resistance of all active
electrical components checked in accordance
with DIN 57117 and DIN 43539, VDE 0117
and VDE 0520.
Measurement voltage > nominal voltage <
500 V. Insulation is considered correct when
it is measured in relation to the chassis and is
higher than 1000 ohm/V of nominal voltage.
Please contact your Service for this test.
50
108043405 [EN] 135