3 Safety
Safety tests
Measuring battery insulation resistance
NOTE
Nominal battery voltage < test voltage < 500V.
Measure insulation resistance using a
suitable meter.
The insulation resistance is sufficient when it
has a nominal value of at least 1000 Ohms/V
against the chassis.
Ask our service department.
Measuring the insulation resistance of
the electrical system
NOTE
Nominal battery voltage < test voltage < 500V.
Before testing the cir
cuit, check that it is
electrically dead.
Measure insulation resistance using a
suitable meter.
The insulation resistance is sufficient when it
has a nominal value of at least 1000 Ohms/V
against the chassis.
Ask our service depa
rtment.
30
50108043405 [EN]