WARNING/FAULT CODES
If a warning/fault occurs which would prevent the printer from operating, the printer will display a code and the
action required.
FAULT CODE CHART
Note: If the error code is not listed below or the printer continues to display an
error code, contact your Service Provider.
Note: Fault codes will cause the part to stop building and the part cannot be
recovered.
Fault Codes Displayed in the
Mojo Control Panel Code Name Recommendation
8 Door open during build. Cycle power and restart part.
9 Cover open during build. Cycle power and restart part.
10 Gantry (U motor) has lost position. Cycle power and restart part.
11 Gantry (V motor) has lost position. Cycle power and restart part.
12 Platen (Z motor) has lost position. Cycle power and restart part.
22 Model heater fault. Replace model QuickPack Print Engine.
23 Support heater fault. Replace support QuickPack Print Engine.
31 Model print engine temperature
fault.
Replace model QuickPack Print Engine.
32 Support print engine temperature
fault.
Replace support QuickPack Print Engine.
51 Printer control error. Cycle power and restart part.