S Class 2 cutter Service manual
Replacements guidelines 2-20
25. Touch screen calibration
26. Media sensor calibration
27. Coil setup
28. Knife calibration
29. OPOS offset calibration
30. Right margin calibration
31. Media length calibration
32. Extra pen offset calibration
17. Remove the right-hand cover (see Section 2.4, Removing the right-hand cover).
18. Disconnect the various connectors. Pay close attention to the positioning of the
connectors. They should be returned to their original location when re-installed.
19. Remove the flat cable(s) for the head by pulling the flat cable connector up. On both sides
of the connector cover there is a small protuberance that you can pry up using a
screwdriver. Gently pull the flat cable(s) out of the connector.
Note:
The D series has only one flatcable. The T series have two flatcables
20. Remove 4 screws.
To re-install, proceed in the reverse order of removal. Make sure to firmly tighten all screws.
Note:
Be very careful while reinstalling the flat cables. If they are not put back in
correct, then both head and main board are irreversibly damaged.