EasyManuals Logo

Sun Microsystems SPARCengine Ultra AXi User Manual

Sun Microsystems SPARCengine Ultra AXi
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
2-14 SPARCengine Ultra AX
i
OEM Technical Manual May 1999
2.4 Reliability
MTBF values are calculated.
When installed, the minimum MTBF of the CPU fan is 75,000 hours.
2.5 Environmental
Operating Non-Operating
Temperature (board
ambient) 0°Cto+55°C -40°Cto+70°C
Air flow requirement 300 lfm at CPU heatsinks
Humidity 5% to 95% 5% to 95%
RH non-condensing RH non-condensing
Shock 6 G peak, 11ms, 10 pulses 15 G peak, 11ms, 3 pulses
Vibration 0.25G, 2 sweeps, 5Hz ~ 500Hz 1.0 G, 2 sweeps, 5Hz ~ 500Hz
@ 1 Octave / min @ 1 Octave/min
Altitude 10,000 ft. (3,408 M) 40,000 ft. (12,192 M)
ESD --- 15.0KV 100% Soft, 25% Hard
CPU/Memory/Fan
Configuration
Mean Time Between Failure
MTBF (Hours)
Annualized Failure Rate
(AFR)
[1]
1. Assumes 8,760 power-on hours per year.
No CPU
No Memory
267,000 3.28%
CPU Module Installed
32 MB Memory
171,600 5.10%
CPU Module Installed
128 MB Memory
164,300 5.33%

Table of Contents

Other manuals for Sun Microsystems SPARCengine Ultra AXi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems SPARCengine Ultra AXi and is the answer not in the manual?

Sun Microsystems SPARCengine Ultra AXi Specifications

General IconGeneral
BrandSun Microsystems
ModelSPARCengine Ultra AXi
CategoryMotherboard
LanguageEnglish