Chapter 4 Servicing Motherboard Components 4-45
10. Remove the jumper from position 2-4, and replace it back to its original
position.
11. Install the top cover.
See Section 6.1, “Installing the Top Cover” on page 6-2.
12. Slide the server into the rack.
See Section 6.3, “Returning the Server to the Normal Rack Position” on page 6-4.
13. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See Section 6.4, “Powering On the Server” on page 6-5.
14. Power on the server.
See Section 6.4, “Powering On the Server” on page 6-5.
The password is reset.
4.10.4 Resetting NVRAM Using a Jumper
To clear the NVRAM using a jumper:
1. Power off the server.
See Section 2.4, “Powering Off the Server” on page 2-3.
2. Disconnect the power cord (or cords) from the power supply (or supplies).
See Section 2.4, “Powering Off the Server” on page 2-3.
3. Extend the server into the maintenance position.
See Section 2.5, “Extending the Server to the Maintenance Position” on page 2-5.
4. Attach an antistatic wrist strap.
See Section 2.7, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-9.
5. Remove the top cover.
See Section 2.8, “Removing the Top Cover” on page 2-11.
6. Locate the jumper J33.
The jumper is on the rear of the motherboard, below PCIe slot 2, PCIE riser 2.
7. Place the jumper on position 1-3.
8. Power on the server and boot until message about NVRAM has been cleared.
9. Power off the server, and remove AC power.