4-46 Sun Fire X4450 Server Service Manual • November 2009
10. Remove the jumper from position 1-3, and replace it in its original location.
11. Install the top cover.
See Section 6.1, “Installing the Top Cover” on page 6-2.
12. Slide the server into the rack.
See Section 6.3, “Returning the Server to the Normal Rack Position” on page 6-4.
13. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See Section 6.4, “Powering On the Server” on page 6-5.
14. Power on the server.
See Section 6.4, “Powering On the Server” on page 6-5.
NVRAM is cleared.
4.11 Recovering from Corrupt Service
Processor Software
If the SP (service processor) software becomes corrupted, you can reinstall the default
SP software image from the Tools and Drivers CD.
You need:
■ The Tools and Drivers CD.
■ A bootable USB flash device.
■ A jumper cap. The server has a jumper cap installed on the motherboard, next to
the AST 2000 chip.
4.11.1 Recovering from Corrupt SP Software
1. Copy the following SP files from the Tools and Drivers CD, located in the
BMCrecovery directory, to a USB flash device.
■ SOCFLASH.EXE
■ DOS4GW
■ BMC Binary (The SP Binary file)
2. Remove AC power from the server to be flashed.
See Section 2.4, “Powering Off the Server” on page 2-3.