4-26 Sun Fire X4450 Server Service Manual • November 2009
4. Remove the PCIe riser board.
See Section 4.5, “Servicing PCIe Risers” on page 4-20.
5. Remove the PCI filler panel.
PCIe filler panels are located in the motherboard back panel.
6. Insert the PCIe card into the correct slot on the riser board. (
FIGURE 4-15)
7. Replace the riser board.
a. Slide the riser back until it seats in its slot in the back panel.
b. Tighten the captive No. 2 Phillips screw securing the riser to the
motherboard.
8. Install the top cover.
See Section 6.1, “Installing the Top Cover” on page 6-2.
9. Slide the server into the rack.
See Section 6.3, “Returning the Server to the Normal Rack Position” on page 6-4.
10. Connect any data cables required to the PCIe card.
Route data cables through the cable management arm.
11. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See Section 6.4, “Powering On the Server” on page 6-5.
12. Power on the server.
See Section 6.4, “Powering On the Server” on page 6-5.