Chapter 4 Servicing Motherboard Components 4-33
Caution The drive data cables are delicate. Carefully connect them and make sure
that they are seated properly when servicing the motherboard.
10. Reinstall the memory tray.
See Section 4.2.2, “Installing the Memory Tray” on page 4-13.
11. Loosen the captive retaining screw that holds the front end of the riser to the
motherboard.
Be careful when routing the drive cables so they don't get pinched and are
underneath the ribs on the support.
12. Reinstall the PCIe cards and risers.
See Section 4.5.2, “Installing a PCIe Riser” on page 4-21.
13. Reinstall the top cover.
See Section 6.1, “Installing the Top Cover” on page 6-2.
14. Reinstall the server into the rack.
See Section 6.2, “Reinstalling the Server in the Rack” on page 6-3.
15. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See Section 6.4, “Powering On the Server” on page 6-5.
16. Power on the server.
See Section 6.4, “Powering On the Server” on page 6-5.