EasyManua.ls Logo

SUNSTONE CDDP-A - Holding Registers

SUNSTONE CDDP-A
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Questions? Call or Text +1-801-658-0015 • 63
e Micro Welder Experts
Index Discrete Input Note
23
Previous Weld Results P2 Enabled
24
E-Stop State
HOLDING REGISTERS
Index Holding Register Length Minimum Maximum Note
0
Remote Schedule Select Mode
1 See Table See Table
1
Pulse 1 Power Comparator Limit Upper
1 0x0000
0x4E20
daW
2
Pulse 1 Power Comparator Limit Lower
1 0x0000
0x4E20
daW
3
Pulse 2 Power Comparator Limit Upper
1 0x0000
0x4E20
daW
4
Pulse 2 Power Comparator Limit Lower
1 0x0000
0x4E20
daW
5
Pulse 1 Current Comparator Limit Upper
1 0x0000
0x2710
A
6
Pulse 1 Current Comparator Limit Lower
1 0x0000
0x2710
A
7
Pulse 2 Current Comparator Limit Upper
1 0x0000
0x2710
A
8
Pulse 2 Current Comparator Limit Lower
1 0x0000
0x2710
A
9
Pulse 1 Voltage Comparator Limit Upper
1 0x0000
0x4E20
mV
10
Pulse 1 Voltage Comparator Limit Lower
1 0x0000
0x4E20
mV
11
Pulse 2 Voltage Comparator Limit Upper
1 0x0000
0x4E20
mV
12
Pulse 2 Voltage Comparator Limit Lower
1 0x0000
0x4E20
mV
13
Weld Head Settings Squeeze Delay
1 0x0096
0x2710
mV
14
Weld Head Settings Hold Delay
1 0x0001
0x2710
ms
15
Energy Total
2 0x0000015E
0x00030D40
(200000),
0x00061A80
(400000),
0x000927C0
(600000),
0x00124F80
(1200000)
mWs
17
Energy Pulse 1
2 0x00000064
0x0000EA60
(200000),
0x0001D4C0
(400000),
0x0002BF20
(600000),
0x00057E40
(1200000)
mWs

Table of Contents