Byte 0 1 2 3 4 5 6 7
Name Tempera-
ture Alarm
- State
Compara-
tor Alarm
- State
Electrode
Stuck
Alarm -
State
Weld
Counter
Alarm -
State
Part
Check
Alarm -
State
Trigger
Alarm -
State
Wrong
Trigger
Alarm -
State
Tempera-
ture Warn-
ing - State
Type bool bool bool bool bool bool bool bool
Byte 8 9
Name
Compara-
tor Warning
- State
Weld
Counter
Warning -
State
Type
bool
bool

Byte 0 1 2 3 4 5 6 7
Name Total Samples P1 State
Index
P2 State
Index
Starting Voltage (mV)
Type uint16 uint8 uint8 uint32
Byte 8 9 10 11 12 13 14 15
Name
Time - Pulse 1 - Start
Time - Pulse 1 - Finish Time - Pulse 2 - Start Time - Pulse 2 - Finish
Type
uint16
uint16 uint16 uint16
Byte 16 17 18 19 20 21
Name Total Duration Pulse 1 - Duration Pulse 2 - Duration
Type uint16 uint16 uint16

Byte 0 1 2 3 4 5 6
Name Hardware
E-Stop
Error -
Heartbeat
Error -
Overtemp
Error -
Terminal
Voltage
Error -
Capacitor
Overvoltage
Error -
Capacitors
not Charging
Modbus
E-Stop
Type bool bool bool bool bool bool bool